User Tools

Site Tools


office

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
office [2023/03/29 08:19] sysadmoffice [2023/07/19 07:48] sysadm
Line 1: Line 1:
 +  * Destination IP table:
 +  *  
 +  * Name
 +  * IP
 +  * Expected Latency(ms)
 +  * EAST-BING
 +  * 13.107.21.200
 +  * 45
 +  * EAST-TWITTER
 +  * 117.18.232.102
 +  * 45
 +  * EAST-ZENLAYER
 +  * 129.227.71.27
 +  * 70
 +  * EAST-FAR-EDGECAST
 +  * 117.18.232.184
 +  * 45
 +  * INDIA-AKAMAI
 +  * 23.9.65.23
 +  * 40
 +  * WEST-UK-VIJU-CLOUD
 +  * 176.58.109.199
 +  * 185
 +  * WEST-USA-IMO
 +  * 192.12.31.101
 +  * 300
 +  * WEST-UK-TELEGRAM
 +  * 149.154.167.151
 +  * 185
 +  * WEST-UK-AMAZON
 +  * 54.239.34.171
 +  * 200
 +
 +
   *    * 
   * CLR LINK P2P check    * CLR LINK P2P check 
Line 138: Line 172:
 In some cases, the signal strength of the incoming signal may be too strong for the receiving device if the distance between the two devices is too short. Using an attenuator can help reduce the signal strength to a more appropriate level. In some cases, the signal strength of the incoming signal may be too strong for the receiving device if the distance between the two devices is too short. Using an attenuator can help reduce the signal strength to a more appropriate level.
  
-[~DHPALPLR-03]display optical-module base information interface 100GE0/10/+  * [~DHPALPLR-03]display optical-module base information interface 100GE0/10/
-=============================================================================== +  Optical Transceiver Base Information 
-Optical Transceiver Base Information +  Card10-Port1 
-=============|================================================================= +  Factor/Module               : QSFP28 
-Card10-Port1 +  Standard                    : 100GBASE-LR4 
--------------|----------------------------------------------------------------- +  Vendor PN                   : 6C-QSFP28-LR4 
-Factor/Module               : QSFP28 +  Vendor Name                 : 6COM 
-Standard                    : 100GBASE-LR4 +  Transceiver Maximal BW      : 100G 
-Vendor PN                   : 6C-QSFP28-LR4 +  Transceiver Mode            : SingleMode 
-Vendor Name                 : 6COM +  Connector Type              : LC 
-Transceiver Maximal BW      : 100G +  WaveLength                  : 1295.56nm 1300.05nm 1304.58nm 1309.14nm 
-Transceiver Mode            : SingleMode +  Transceiver Distance        : 10km 
-Connector Type              : LC +  Rx Optical Power Total      : 8.29dBm 
-WaveLength                  : 1295.56nm 1300.05nm 1304.58nm 1309.14nm +  Tx Optical Power Total      : 8.33dBm 
-Transceiver Distance        : 10km +  Rx Power Warning Range      : [-11.598,  4.500]dBm 
-Rx Optical Power Total      : 8.29dBm +  Tx Power Warning Range      : [-5.300,  4.500]dBm 
-Tx Optical Power Total      : 8.33dBm +  Rx Optical Power[0]         : 1.78dBm 
-Rx Power Warning Range      : [-11.598,  4.500]dBm +  Tx Optical Power[0]         : 2.28dBm 
-Tx Power Warning Range      : [-5.300,  4.500]dBm +  Rx Optical Power[1]         : 2.31dBm 
-Rx Optical Power[0]         : 1.78dBm +  Tx Optical Power[1]         : 2.24dBm 
-Tx Optical Power[0]         : 2.28dBm +  Rx Optical Power[2]         : 2.33dBm 
-Rx Optical Power[1]         : 2.31dBm +  Tx Optical Power[2]         : 2.19dBm 
-Tx Optical Power[1]         : 2.24dBm +  Rx Optical Power[3]         : 2.61dBm 
-Rx Optical Power[2]         : 2.33dBm +  Tx Optical Power[3]         : 2.54dBm 
-Tx Optical Power[2]         : 2.19dBm +  The Optical Match Result    : Normal 
-Rx Optical Power[3]         : 2.61dBm +  The Vendor Private Information : NA 
-Tx Optical Power[3]         : 2.54dBm +  *  
-The Optical Match Result    : Normal +  *  
-The Vendor Private Information : NA +  * [~DHPALPLR-03]display optical-module base information interface 100GE0/10/
-=============|=======================+  *  
 +  * Optical Transceiver Base Information 
 +  *  
 +  * Card10-Port1 
 +  *  
 +  * Factor/Module               : QSFP28 
 +  * Standard                    : 100GBASE-LR4 
 +  * Vendor PN                   : 6C-QSFP28-LR4 
 +  * Vendor Name                 : 6COM 
 +  * Transceiver Maximal BW      : 100G 
 +  * Transceiver Mode            : SingleMode 
 +  * Connector Type              : LC 
 +  * WaveLength                  : 1295.56nm 1300.05nm 1304.58nm 1309.14nm 
 +  * Transceiver Distance        : 10km 
 +  * Rx Optical Power Total      : 7.20dBm 
 +  * Tx Optical Power Total      : 8.33dBm 
 +  * Rx Power Warning Range      : [-11.598,  4.500]dBm 
 +  * Tx Power Warning Range      : [-5.300,  4.500]dBm 
 +  * Rx Optical Power[0]         : 0.67dBm 
 +  * Tx Optical Power[0]         : 2.27dBm 
 +  * Rx Optical Power[1]         : 1.31dBm 
 +  * Tx Optical Power[1]         : 2.24dBm 
 +  * Rx Optical Power[2]         : 1.34dBm 
 +  * Tx Optical Power[2]         : 2.20dBm 
 +  * Rx Optical Power[3]         : 1.38dBm 
 +  * Tx Optical Power[3]         : 2.53dBm 
 +  * The Optical Match Result    : Normal 
 +  * The Vendor Private Information : NA 
 + 
 + 
 + 
 + 
 +  * as-path-set CHINA-TELECOM-EQUINIX-AS-BLOCK 
 +  *   ios-regex '^12345_', 
 +  *   ios-regex '^32934_', 
 +  *   ios-regex '^15169_', 
 +  *   ios-regex '^174_', 
 +  *   ios-regex '^7473_', 
 +  *   ios-regex '^9498_', 
 +  *   ios-regex '^6453_', 
 +  *   ios-regex '^132602_', 
 +  *   ios-regex '^64074_', 
 +  *   ios-regex '^132884_', 
 +  *  // ios-regex '^_'// 
 +  * end-set 
 +  * ! 
 + 
 + 
 +  * display  ip as-path-filter BTTB-RAMNA-AS-IN 
 +  * As path filter name: BTTB-RAMNA-AS-IN 
 +  *     index: 10            permit     ^17494$ 
 +  *     index: 20            permit     ^17494 63932_ 
 +  *     index: 30            permit     ^17494 133890_ 
 +  *     index: 40            permit     ^17494 45532_ 
 +  *     index: 50            permit     ^136759_  
 + 
 + 
 +  * RP/0/RP0/CPU0:SINEQCR-01#show running-config interface TenGigE0/0/0/
 +  * Tue Mar 14 19:54:47.955 BDT 
 +  * interface TenGigE0/0/0/
 +  * description @@ SMW5-LINK20-TO-UTTARA-AGG-VIA-EQUINIX-SG3-SMW5-BSCCL-SCL @@ 
 +  * ipv4 address 103.199.87.72 255.255.255.254 
 +  * ipv6 address 2405:1500:0:2::33d/126 
 +  * ipv6 enable 
 +  * **carrier-delay up 20000 down 20000** 
 +  * shutdown 
 +  * load-interval 30 
 +  * ipv4 access-group BTRC-NEW-BLOCK ingress 
 +  * ipv4 access-group BTRC-NEW-BLOCK egress 
 +  * ! 
 + 
 +The hold up time and hold down time can be used to prevent routing loops and to improve the stability of the network. For example, if a router has a hold up time of 10 seconds and a hold down time of 20 seconds, and it declares a neighbor down, it will wait 10 seconds for a hello packet from the neighbor before declaring the neighbor down. If the router does not receive a hello packet from the neighbor within 10 seconds, it will wait 20 seconds before trying to re-establish the neighbor adjacency. This helps to prevent routing loops from occurring if the neighbor is only temporarily unavailable. 
 + 
 +The hold up time and hold down time can also be used to improve the stability of the network by preventing flapping. Flapping occurs when a routing loop is created and then broken, and then created again. This can happen if a router is constantly declaring neighbors down and then up again. The hold up time and hold down time can help to prevent flapping by preventing a router from declaring a neighbor down too quickly. 
 + 
 + 
 +  * interface Ethernet1/21 
 +  *   description ICC-NIX_TO-ODF-1 T5 P12_iccc_160220_022_ic 
 +  *   switchport access vlan 777 
 +  *   spanning-tree guard root 
 +  *   switchport port-security 
 +  *   switchport port-security mac-address C4AD.3468.6AC2 
 +  *   no shutdown 
 + 
 +---------------spanning ------------------- 
 + 
 +show  running-config i spann 
 +no spanning-tree vlan 1565,1933,2389,2463,3029,3442,3826 
 +DHUTRCLSW-01# show  running-config | i spa 
 +no spanning-tree vlan 1565,1933,2389,2463,3029,3442,3826
  
-[~DHPALPLR-03]display optical-module base information interface 100GE0/10/+HUTRCLSW-01(config)# no spanning-tree vlan 1467,1565,1933,2389,2463,3029,3442,3826
-=============================================================================== +
-Optical Transceiver Base Information +
-=============|================================================================= +
-Card10-Port1 +
--------------|----------------------------------------------------------------- +
-Factor/Module               : QSFP28 +
-Standard                    : 100GBASE-LR4 +
-Vendor PN                   : 6C-QSFP28-LR4 +
-Vendor Name                 : 6COM +
-Transceiver Maximal BW      : 100G +
-Transceiver Mode            : SingleMode +
-Connector Type              : LC +
-WaveLength                  : 1295.56nm 1300.05nm 1304.58nm 1309.14nm +
-Transceiver Distance        : 10km +
-Rx Optical Power Total      : 7.20dBm +
-Tx Optical Power Total      : 8.33dBm +
-Rx Power Warning Range      : [-11.598 4.500]dBm +
-Tx Power Warning Range      : [-5.300 4.500]dBm +
-Rx Optical Power[0]         : 0.67dBm +
-Tx Optical Power[0]         : 2.27dBm +
-Rx Optical Power[1]         : 1.31dBm +
-Tx Optical Power[1]         : 2.24dBm +
-Rx Optical Power[2]         : 1.34dBm +
-Tx Optical Power[2]         : 2.20dBm +
-Rx Optical Power[3]         : 1.38dBm +
-Tx Optical Power[3]         : 2.53dBm +
-The Optical Match Result    : Normal +
-The Vendor Private Information : NA +
-=============|=================================================================+
office.txt · Last modified: 2024/05/05 16:51 by sysadm